Choose for the location
Use local solar conditions and installation orientation to assess a suitable tilt.
MEU-2D / PRODUCT PLATFORM
A repeatable module combining two parking bays, 6.55kWp solar generation and a foldable steel structure.
CURRENT DESIGN CONFIGURATION
Factory-prefabricated structure and interfaces are deployed, locked and connected on site to reduce wet work and support future expansion.
Panel tilt adjustment: −10° to +10°; reference angle and configuration require project engineering confirmation.

This is the current design configuration. Final structural, electrical and foundation parameters require project-specific verification.

FOLD · MOVE · DEPLOY
Folding is not a visual feature; it is a structural strategy for manufacturing, transport, installation and asset redeployment.
MEU CAPABILITIES
MEU panels support adjustment from −10° to +10°. Select an appropriate angle for local sunlight, orientation and shading to improve solar capture and generation performance.
Use local solar conditions and installation orientation to assess a suitable tilt.
Account for shading, drainage, parking clearance and wind loads in structural verification.
The reference angle, adjustment method, locking requirements and permitted adjustments follow formal engineering documents. This does not imply solar tracking or maximum output at every site.
BUILT FOR REAL SITES
Beyond solar generation and shelter, projects can evaluate charging, storage, lighting, security and information modules.

FOUNDATION INTERFACES
Foundation selection requires project-specific engineering around actual site conditions.
MEU ENERGY ARCHITECTURE
From grid-tied self-consumption and zero export to hybrid storage, every configuration requires site-specific engineering.
PV modules → grid inverter → AC distribution → user loads → grid supplement
For factories, parks and common-property loads
Adds smart meter, CTs, export control and power regulation; it remains grid-connected.
For commercial sites with export restrictions
Adds hybrid inverter, battery, BMS, EMS and critical-load interfaces.
For backup, tariff management and microgrids
MEU CAPABILITIES
MEU software connects individual canopies and whole-station operating data to help you monitor generation, locate issues and track returns across distributed assets.
Review station-wide operation, then inspect generation status and energy output for each canopy.
Locate the affected canopy and connected equipment and receive mobile alerts to support timely investigation and response.
Track generation and estimated returns per canopy and station using tariffs, self-consumption and exported energy.
Monitoring and alerts support earlier detection and response to help reduce electrical fault and fire risks. They do not replace electrical protection, fire safety or on-site maintenance, or guarantee zero risk.
Returns are estimates based on project data and tariffs, not settled income. Monitoring detail, update frequency, alert channels and delivery depend on connected equipment, connectivity and the agreed service configuration.
SAFETY · SERVICE LIFE
PV is not inherently unsafe, and no solution can promise zero fire risk. Safety depends on design, equipment, installation, protection and lifecycle inspection.
Independent fixed structure with a simple load path; wind, snow, foundation and impact still require verification.
Adds dead and wind loads to an existing roof; residual life, capacity, connections, waterproofing and corrosion must be verified.
0 kg/m²added load to factory roofGround-supported steel structure; the module and foundation still require project-specific checks.
Usually has no generation system and fewer electrical ignition sources; lighting or charging still needs protection.
The DC system is close to the roof, insulation and production space; consequences depend on roof materials, fire separation and work controls.
6.55 kWpcurrent DC capacity boundaryLocated in open parking and separated from the factory roof; DC arc and electrical fault risks remain.
Visible structural joints; maintenance focuses on fasteners, drainage, coating and foundations.
Height, roof access and limited space below modules can constrain inspection, isolation and replacement.
≥ 1 / yearcomprehensive electrical inspection targetAdd checks after extreme weather, alarms or works; final frequency follows the O&M plan.
Life is governed mainly by structure, corrosion protection, connections and maintenance.
In addition to PV equipment life, it is constrained by the building’s residual life, reroofing cycle and leak repairs.
25 yearscurrent structural design working-life targetLayered maintenance for structure, electrical system and modules; final life follows calculations, exposure class and contract.
Wind, snow, seismic, ground, slab, clearance and vehicle impact enter formal structural design.
Use compatible modules, connectors, cables and protection, with grounding, lightning, overcurrent and DC fault protection.
Inspect temperature, connectors, insulation, fasteners, coating, drainage and alarms; isolate faults promptly.
0 kg/m² means the independent MEU foundation adds no load to the factory roof. 6.55kWp, at least one comprehensive electrical inspection per year and a 25-year structural working-life target are current configuration or design/O&M targets, not unconditional guarantees. Final values require qualified survey, calculations, exposure classification, equipment selection, local codes, acceptance and contract.
SITE RISK CONTROLS
Factory rooftop PV requires consideration of electrical safety, roof materials, hot work and fire-service access. MEU combines independent placement, canopy monitoring and operational procedures to help limit exposure of production areas, subject to project design, equipment and validation.
Ground-supported placement, designed separation distances and clear access can help avoid continuous spread paths through walls or adjoining canopies. Vehicles, charging and storage still need separate assessment.
Map canopy IDs to monitored circuits and equipment to narrow investigations. Mobile alerts support notification; generation monitoring is not fire detection, and rooftop PV can use similar monitoring.
Include notification delivery, acknowledgement, qualified investigation and safe isolation in operating procedures. Local isolation depends on electrical design; automatic suppression or fixed response times are not promised.
At acceptance, record: fault onset → detection → mobile notification → acknowledgement → safe isolation or on-site response. Actual timing depends on sensing and protection, connectivity and staffing, and requires test evidence.
Public cases illustrate incident mechanisms, not industry incident rates or proof that MEU would prevent similar events. The current 6.55 kWp unit rating is not a fire-spread boundary or a maximum-loss limit.
Read 2025–2026 international cases and sources →VALUE COMPARISON
A conventional canopy provides shelter. MEU-2D adds generation, relocation and expansion within a similar footprint.
Fixed shelter structure
Generates, relocates and expands
The premium adds more than material: 6.55kWp generation, a relocatable structure and interfaces for future expansion.
Parking space becomes infrastructure that continuously generates energy.
Evaluated disassembly and relocation can reduce the sunk risk of fixed infrastructure.
Charging, storage, lighting and security modules can be added as the project evolves.
The conventional-canopy reference includes installation and a 13% VAT special invoice, excluding freight. MEU-2D excludes freight and battery storage; installation scope follows the formal quotation. The canopy price is a single market reference, not an industry-wide price.
CONFIGURE YOUR MEU
Select brand, appearance and functional preferences; final configuration is verified against electrical compatibility, structural safety, availability and budget.
Choose module brand and appearance; model, power and dimensions remain subject to structural and electrical verification.
Options: standard / all-black / customer-specifiedSelected around grid mode, capacity, MPPT, grid system and monitoring requirements.
Options: grid-tied / zero-export / hybrid-readyStructure color can match architecture, site identity and environment, confirmed by color sample or first article.
Coating and corrosion class depend on coastal, industrial and other exposureAdd energy and digital capabilities to the standard generation unit based on operating goals.
All options require electrical capacity, installation space and approval checksBrands are preferences, not fixed supply commitments. Final brand, model, warranty, lead time, color, coating and price follow the approved configuration schedule and contract; substitutions must meet or exceed confirmed technical requirements.
Submit preferencesSTART WITH YOUR SITE